36
Network HOST NAME display the name of the recorder .IP is set by using
ST or input the exact numbers to change the IP address(IP address setting
can only be realized in this term),and then set the correspond
SUBNETMASK and GATEWAY WEB PORT、TCP PORT :in
accordance with the user’s network condition, the default port is 00080 and
37777.MONITOR can be selected by using ST(TCP/IP、UDP).Reserve
the setting in SAVE, and restart the recorder.
Note: UDP:The users with manage can monitor each channel freely, and other users can only view after them. Max
5 users can log in.
TCP Protocol:All users are able to monitor any channel. User shall select according to necessity. If the
transmission is under Internet, TCP should be chosen. 2 users at maximum
Motion Detection Select the relevant channel in CH. OUTPUT “●” means
startup alarm relay when detect the motion image; “○” means
non alarm relay. Open or close the function in DELAY
Choose how long you want to continue the recording(1/6、
1/2、1、3……30min)after motion detection is finished.
PRERECORD save the motion detection. SENS has three
levels: LOW, NORMAL, HIGH .TIMING1 、TIMING2
the way of setting the period of time is the same as the setting of ALARMSETTING.
AREA can be accessed by pressing ENTER. The setting area can be divided in 192 sections. Red
section means the current cursor position, and green section is the motion detection area. The no
color area is no motion detection area. Press Fn to locate the current section, then move the cursor to
cover the MD needed area; press Fn again to choose the MD area.
RS232 COMFUNC select super terminal or Keyboard.
BAUDRATE select correspond baud rate. DATA BIT selection 1-8.
STOP BIT three selection 1、1.5 and 2.
VERIFY odd and even
MOTION DETECTION
CH 01
No
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ALMOUT
●○○○○○○○○○○○○○○
RECORD
●○○○○○○○○○○○○○○
DELAY 30 SEC TIPS OFF
PRECORD ON
LEVEL HIGH
AREA SET
TIME1 10:00AM—02:00PM OFF
TIME2 10:00AM—02:00PM OFF
DEFAULT SAVE CANCEL
NETWORK
HOSTNAME DVR1604
IP 192.168.000.111
SUBNETMASK 255.255.255.000
GATEWAY 192.168.000.001
WEB PORT 00080
TCP PORT 37777
MONITOR TCP
DEFAULT SAVE CANCE
RS232
COMFUNC
HYPETERM
BAUDRATE 115200
DATA BIT 8 BIT
STOP BIT 1 BIT
VERYIFY NULL
DEFAULT SAVE CANCEL